More than just
for the fun of it swimming also contributes significantly to your
family's health. |
 |
Swimming is
"just what the doctor ordered" for maintaining health and vigor,
especially during those "neglected" middle years.
|
|

Why an OTF Pool Heater
Means
|
 |
|
pool heaters pool heater POOL HEATERS POOL
HEATER pool heaters pool heater POOL HEATERS POOL HEATER pool heaters
pool heater POOL HEATERS POOL HEATER pool heaters pool heater POOL HEATERS
POOL HEATER pool heaters pool heater POOL HEATERS POOL HEATER pool heaters
pool heater POOL HEATERS POOL HEATER pool heaters pool heater POOL
HEATERS POOL HEATER pool heaters pool heater POOL HEATERS POOL HEATER pool
heaters pool heater POOL HEATERS POOL HEATER pool heaters pool heater
POOL HEATERS POOL HEATER pool heaters pool heater POOL HEATERS POOL HEATER
pool heaters pool heater POOL HEATERS POOL HEATER pool heaters pool heater
POOL HEATERS POOL HEATER pool heaters pool heater POOL HEATERS POOL
HEATER pool heaters pool heater POOL HEATERS POOL HEATER pool heaters pool
heater POOL HEATERS POOL HEATER pool heaters pool heater POOL HEATERS POOL
HEATER pool heaters pool heater POOL HEATERS POOL HEATER pool heaters
pool heater POOL HEATERS POOL HEATER pool heaters pool heater POOL HEATERS
POOL HEATER
 |
An OTF pool heater maintains temperature with fuel efficiency and low maintenance
|
|
 |
Pool heaters preserve the beauty of your pool area since there is no
chimney or special housing needed
|
|

| FEATURES - A
THERMO-DYNAMICS OIL-FIRED POOL HEATER IS A SMART ADDITION . CAN BE USED TO
HEAT POOL ENCLOSURE OR ADJACENT BUILDING . HIGH TEMPERATURE HARD REFRACTORY
COMBUSTION CHAMBER |
The OTF design features:
 |
durable, long lasting
construction.. . . built to National Board Specifications Comes in
Outdoor (OTF) or Indoor (ITF) Versions
|
|
 |
all-copper indirect heat exchanger design practically eliminates
corrosion, scaling and condensation problems
|
|
 |
aluminized flue collector and firebox assembly withstands atmospheric
corrosion
|
|
 |
flame retention forced draft oil burner provides efficient combustion;
easy access for maintenance and adjustment; UL listed components
|
 |
|
 |
precast refractory combustion chamber is surrounded by insulating
pellets to keep heat loss through the base to a minimum
|
|
 |
preassembled for ease of installation
|

Model- OTF |
510 |
801 |
1010 |
1600 |
Gross Input |
140,000 |
210,000 |
280,000 |
350,000 |
*Gross Output- BTU/HR |
109,200 |
163,800 |
218,400 |
273,000 |
Flue Pipe Diam |
6" |
6" |
8" |
8" |
Firing Rate- GPH |
1.00 |
1.50 |
2.00 |
2.50 |
Width |
22" |
22" |
26 1/4" |
26 1/4" |
Length |
31" |
31" |
34" |
34" |
Height |
38 1/2" |
38 1/2" |
45" |
45" |
Approx. Shipping Weight
|
397 |
434 |
602 |
620 |
*Use Gross Output - BTU/HR to estimate boiler size
|
|
|
|
Standard Equipment
OTF- Aluminum jacket with self venting / ITF- flush jacket with baked
enamel finish, Boiler body with combustion chamber installed, theraltimeter, completely
assembled and packaged with oil burner, cadcell relay, pool & limit control, relief
valve, indirect pool heating coil SC-150 (510/801) SC-200 (901/1600) with 1 1/2"
I.P.S. tappings.
|
|
|
|
|
|

|
|
|
|
|
|
There are many factors related to proper sizing of pool heater. We
recommend that you contact your installing dealer for help in determining the correct size
for your particular application. |
|
|
|
POOL HEATER SIZING
CHART
HEAT LOSS FROM POOL SURFACE
B.T.U.'S PER HOUR
|
Surface Area of Pool,
Sq. Ft.
|
Desired Pool
Temperature (°F)
|
Approximate Gallons
|
80°
|
85°
|
90°
|
500
|
137,000 Btu.
|
155,000 Btu.
|
200,000 Btu.
|
20,000
|
600
|
166,000 Btu.
|
185,000 Btu.
|
240,000 Btu.
|
24,000
|
700
|
200,000 Btu.
|
218,000 Btu.
|
280,000 Btu.
|
28,000
|
800
|
220,000 Btu.
|
250,000 Btu.
|
320,000 Btu.
|
32,000
|
900
|
248,000 Btu.
|
280,000 Btu
|
360,000 Btu.
|
36,000
|
1000
|
275,000 Btu.
|
310,000 Btu.
|
400,000 Btu.
|
40,000
|
1200
|
330,000 Btu.
|
370,000 Btu.
|
480,000 Btu.
|
48,000
|
1400
|
384,000 Btu.
|
435,000 Btu.
|
560,000 Btu.
|
56,000
|
1600 or larger
|
Refer inquiry to Thermo-Dynamics.
|
Note 1. These heat
losses are based on an assumed wind velocity at the water surface of 5 m.p.h. and an
ambient temperature of 60°F.
Note 2. Where surface area and gallons do not coincide, surface area must take precedence.
For more information on heat loss from spa surfaces, contact Thermo-Dynamics.
|
|
|
|
|