tdlogo.gif (14764 bytes)

S-SERIES/140 PSI PUMP PRESSURE

Home PROFILE DIRECT VENT OIL BOILERS OUTDOOR OS GAS BOILERS POOL HEATERS MANUALS WARRANTY BULLETINS CONTACTS GUESTBOOK


In our ongoing effort to improve dependability and product performance we have changed the burner specifications for out "S" Series boiler to include 140 PSI pump pressure operation.

"S" Series Boiler/Burner Specification - Beckett Model "AFG"

Boiler Size

Pump Pressure

Delavan Nozzle

Air Shutter

Air Band

Burner Head

S-85

140 PSI

.65X80°B

10*

0

F-3

S-100

140 PSI

.75X80°B

8

0

F-3

S-110

140 PSI

.85X80°B

10

0

F-3

S-125

140 PSI

1.00X80°B

10

0

F-12

S-135

140 PSI

1.10X80°B

10

1

F-12

S-150

140 PSI

1.25.X80°B

10

2

F-12

* Low Firing Baffle Installed.

The preceding table includes all the new pump pressure and nozzle data for a typical field operation. As in any good installation, the final burner settings should be made using the proper test equipment.